<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fundación Forpro Albacete &#187; Cables y Accesorios</title>
	<atom:link href="https://www.fundacionforpro.org/blog/category/cables-accesorios/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.fundacionforpro.org</link>
	<description></description>
	<lastBuildDate>Mon, 05 Jan 2026 16:40:54 +0000</lastBuildDate>
	<language>es-ES</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.41</generator>
	<item>
		<title>Cálculo de secciones con Prysmitool</title>
		<link>https://www.fundacionforpro.org/blog/calculo-de-secciones-prysmitool/</link>
		<comments>https://www.fundacionforpro.org/blog/calculo-de-secciones-prysmitool/#comments</comments>
		<pubDate>Mon, 31 Aug 2015 07:45:29 +0000</pubDate>
		<dc:creator><![CDATA[Forpro]]></dc:creator>
				<category><![CDATA[Cables y Accesorios]]></category>
		<category><![CDATA[Instalación eléctrica]]></category>
		<category><![CDATA[Noticias]]></category>

		<guid isPermaLink="false">http://www.fundacionforpro.org/?p=1692</guid>
		<description><![CDATA[<p>La entrada <a rel="nofollow" href="https://www.fundacionforpro.org/blog/calculo-de-secciones-prysmitool/">Cálculo de secciones con Prysmitool</a> aparece primero en <a rel="nofollow" href="https://www.fundacionforpro.org">Fundación Forpro Albacete</a>.</p>
]]></description>
				<content:encoded><![CDATA[<div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-12 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">En anteriores entradas de nuestro blog hemos estado viendo cómo calcular la sección de una línea eléctrica, siempre haciendo uso de técnicas de diseño y cálculo de forma manual, atendiendo a la normativa vigente.</p>
<p style="text-align: justify;">Bien, pues en esta nueva entrada vamos a daros a conocer un software de cálculo de secciones que es muy útil y nos agiliza mucho los cálculos cuando queremos conocer la sección de una línea eléctrica.</p>
<p style="text-align: justify;">Entre la gran variedad de programas informáticos de cálculo de secciones que existen en nuestro entorno profesional, vamos a conocer el programa <strong>Prysmitool </strong>de<strong> Prysmian.</strong></p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>

<div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-info">
	<div class="vc_message_box-icon"><i class="fa fa-info-circle"></i>
	</div><p style="text-align: justify;">Prysmian Group es el líder mundial en la industria de Sistemas y Cables Eléctricos y de Telecomunicaciones orientado en desarrollo tecnológico y futuro sostenible, consulta su página web en:</p>
<h5 style="text-align: center;"><a href="http://es.prysmiangroup.com/es/index.html" target="_blank">Prysmian Cables y Sistemas</a></h5>
</div>
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p>Para comenzar a utilizar el programa de cálculo Prysmitool, tenemos que conocer qué normativa utiliza para saber si se ajusta a la normativa vigente. Indicar que dicho programa de cálculo sigue los criterios del Reglamento Electroténico para Baja Tensión REBT, sin embargo también es aplicable para cálculos más allá del territorio nacional ya que las intensidades admisibles que emplea se corresponden con las de la norma IEC 60364-5-523.</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>

<div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-info">
	<div class="vc_message_box-icon"><i class="fa fa-info-circle"></i>
	</div><p style="text-align: justify;">El REBT remite en su ITC-BT 19 a la norma UNE 20460-5-523, la última actualización de esta norma se produjo en el 2004 y hoy en día se encuentra derogada por la norma UNE HD 60364-5-52:2014 para obtener las intensidades máximas admisibles de los conductores.</p>
<p style="text-align: justify;">La norma internacional a la cual equivale es la  IEC 60364-5-52:2009 (vigente) y conforme nos indica Prysmian, el programa, la norma que utiliza es la versión IEC 60364-5-523 (1999), pudiéndose utilizar esta versión para hacer cálculos bajo norma internacional. Sería conveniente comprobar las modificaciones producidas en la modificación que puedan afectar al cálculo de la sección.</p>
</div>
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Una vez que accedemos a prysmitool, en primer lugar elegiremos la ITC BT del REBT según el tipo de instalación o del emplazamiento que vayamos a calcular.</p>
<p style="text-align: justify;">El importante tener claro la ITC elegida porque después nos indicará los sistemas de instalación y los tipos de cables permitidos según la norma.</p>
<p style="text-align: justify;">La ITC BT 20 es la más general y te muestra gran variedad de sistemas de instalación y tipos de cables.</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


		</div> 
	</div> 
</div><div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-6 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_21.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="169" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_21-300x169.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_2" /></div></a>
		</div> 
	</div> 
		</div> 
	</div> 

	<div class="vc_col-sm-6 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_31.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="198" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_31-300x198.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_3" /></div></a>
		</div> 
	</div> 
		</div> 
	</div> 
</div><div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-12 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p>Una vez seleccionado la ITC, elegimos el sistema de instalación:</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_41.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="199" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_41-300x199.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_4" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p>Y continuamos con los tipos de cable:</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_61.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="196" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_61-300x196.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_6" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Si no tenemos claro el tipo de cable, Prysmian nos ofrece en su catálogo para cables y accesorios de BT, cuáles son los tipos de cables a seleccionar y los podremos consultar en la siguiente tabla orientativa:</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_7.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="135" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_7-300x135.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_7" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>

<div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-vista_blue">
	<div class="vc_message_box-icon"><i class="fa fa-pencil-square-o"></i>
	</div><p>Puedes consultar el catálogo de cables y accesorios para Baja Tensión de Prysmian:</p>
<h5 style="text-align: center;"><a href="http://www.prysmianclub.es/files/content/images/Catalogo_BT_Prysmian_2013_2.pdf" target="_blank">Cables y Accesorios para Baja Tensión</a></h5>
</div>
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">En las siguientes pantallas debemos introducir datos numéricos referentes a tensión e intensidad que nos permitan calcular la sección por el <strong>método de intensidad</strong>, introduciendo datos de intensidad ó potencia, factor de potencia y aquellos coeficientes que nos exija la normativa.</p>
<p style="text-align: justify;">También nos permitirá calcular la sección por el  <strong>método de la caída de tensión</strong>, introduciendo datos de la caída de tensión máxima permitida conforme a la normativa, ya sea en tanto por ciento o en voltios, y la longitud de la línea.</p>

		</div> 
	</div> 
		</div> 
	</div> 
</div><div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-6 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_8.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="198" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_8-300x198.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_8" /></div></a>
		</div> 
	</div> 
		</div> 
	</div> 

	<div class="vc_col-sm-6 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_9.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="197" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_9-300x197.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_9" /></div></a>
		</div> 
	</div> 
		</div> 
	</div> 
</div><div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-12 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;" align="justify">A continuación elegiremos las condiciones de la instalación para que en el cálculo se apliquen los coeficientes de corrección correspondientes que figuran en la normativa de aplicación (agrupamiento, temperatura y exposición al sol para instalaciones al aire y además resistividad térmica del terreno, profundidad del tendido para instalaciones enterradas).</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_10.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="198" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_10-300x198.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_10" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">En la última pantalla aparecerá un resumen con los datos introducidos a lo largo de las pantallas y calcularemos la sección. Además el programa cuenta con la opción de «informe» que nos dará el resultado de nuestro cálculo y se puede generar un informe en pdf, el cual podremos personalizar, guardar, modificar en otro momento, etc.</p>

		</div> 
	</div> 
		</div> 
	</div> 
</div><div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-6 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_11.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="197" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/prysmitool_11-300x197.jpg" class="vc_single_image-img attachment-medium" alt="prysmitool_11" /></div></a>
		</div> 
	</div> 
		</div> 
	</div> 

	<div class="vc_col-sm-6 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/08/informe.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="212" height="300" src="https://www.fundacionforpro.org/wp-content/uploads/2015/08/informe-212x300.jpg" class="vc_single_image-img attachment-medium" alt="informe" /></div></a>
		</div> 
	</div> 
		</div> 
	</div> 
</div><div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-12 wpb_column column_container ">
		<div class="wpb_wrapper">
			<div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>

<div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-vista_blue">
	<div class="vc_message_box-icon"><i class="fa fa-download"></i>
	</div><p>Conoce cómo descargárte el software y visualiza en este vídeo un ejemplo de utilización del programa</p>
<p style="text-align: center;"><a href="https://www.youtube.com/watch?v=A2dwqVMf2G8" target="_blank"><strong>Cálculo de secciones con Prysmitool</strong></a></p>
</div>
		</div> 
	</div> 
</div><div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-12 wpb_column column_container ">
		<div class="wpb_wrapper">
			<div class="vc_empty_space"  style="height: 32px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_raw_code wpb_content_element wpb_raw_html">
		<div class="wpb_wrapper">
			<iframe width="853" height="480" src="https://www.youtube.com/embed/A2dwqVMf2G8?rel=0&amp;showinfo=0" frameborder="0" allowfullscreen></iframe>
		</div> 
	</div> 
		</div> 
	</div> 
</div>
<p>La entrada <a rel="nofollow" href="https://www.fundacionforpro.org/blog/calculo-de-secciones-prysmitool/">Cálculo de secciones con Prysmitool</a> aparece primero en <a rel="nofollow" href="https://www.fundacionforpro.org">Fundación Forpro Albacete</a>.</p>
]]></content:encoded>
			<wfw:commentRss>https://www.fundacionforpro.org/blog/calculo-de-secciones-prysmitool/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Parte 1/2: Cálculo de la Sección de una Línea Eléctrica</title>
		<link>https://www.fundacionforpro.org/blog/calculo-de-la-seccion-de-una-linea-electrica/</link>
		<comments>https://www.fundacionforpro.org/blog/calculo-de-la-seccion-de-una-linea-electrica/#comments</comments>
		<pubDate>Wed, 15 Jul 2015 11:38:21 +0000</pubDate>
		<dc:creator><![CDATA[Forpro]]></dc:creator>
				<category><![CDATA[Cables y Accesorios]]></category>
		<category><![CDATA[Instalación eléctrica]]></category>
		<category><![CDATA[Normativa y Reglamentación]]></category>

		<guid isPermaLink="false">http://www.fundacionforpro.org/?p=1604</guid>
		<description><![CDATA[<p>La entrada <a rel="nofollow" href="https://www.fundacionforpro.org/blog/calculo-de-la-seccion-de-una-linea-electrica/">Parte 1/2: Cálculo de la Sección de una Línea Eléctrica</a> aparece primero en <a rel="nofollow" href="https://www.fundacionforpro.org">Fundación Forpro Albacete</a>.</p>
]]></description>
				<content:encoded><![CDATA[<div class="wpb_row wf-container" style="margin-top: 0px;margin-bottom: 0px" >
	<div class="vc_col-sm-12 wpb_column column_container ">
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p>La sección de un conductor es la superficie que aparece cuando lo cortamos perpendicularmente a su longitud. Por lo general los conductores son cilíndricos, por lo que la sección suele ser un área circular, la cual se expresa en mm2.</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 32px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/07/m03u02-seccionconductor.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="120" src="https://www.fundacionforpro.org/wp-content/uploads/2015/07/m03u02-seccionconductor-300x120.jpg" class="vc_single_image-img attachment-medium" alt="m03u02-seccionconductor" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 32px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Dado que los conductores no son perfectos y poseen una cierta resistencia eléctrica, cuando son atravesados por una corriente eléctrica se producen dos fenómenos:</p>
<ul>
<li style="text-align: justify;">Se calientan y pierden potencia.</li>
<li style="text-align: justify;">Al estar conectados en serie con los aparatos eléctricos que alimentan, se produce una caída de tensión, que hace que se reduzca apreciablemente la tensión, al final de la línea.</li>
</ul>
<p style="text-align: justify;">Éstos son los <strong>dos factores más importantes</strong> que hay que tener en cuenta a la hora de seleccionar la sección más adecuada para una instalación eléctrica.</p>

		</div> 
	</div> 
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">El <strong>cálculo de la sección</strong> de los conductores de una línea viene determinado principalmente por los factores siguientes:</p>
<ul>
<li style="text-align: justify;">Intensidad máxima admisible.</li>
<li style="text-align: justify;">Caída de tensión máxima fijada por el REBT.</li>
</ul>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 32px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<h3 style="text-align: center;"><span style="color: #0000ff;">Cálculo de la sección teniendo en cuenta la intensidad máxima admisible</span></h3>
<p style="text-align: justify;">El calentamiento de un conductor, entre otros factores, depende de la intensidad de corriente que circule por él. Luego, cuanto mayor sea la corriente que circula por un conductor, mayor tendrá que ser la sección de éste para que no se caliente excesivamente.</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 16px" ><span class="vc_empty_space_inner"></span></div>

<div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-info">
	<div class="vc_message_box-icon"><i class="fa fa-info-circle"></i>
	</div><p style="text-align: justify;">Dado que el calor se va a concentrar más en un conductor instalado bajo tubo que en un conductor instalado al aire, también habrá que tener en cuenta, a la hora de determinar la sección, la <strong>forma de instalar los conductores</strong> y la <strong>agrupación de los mismos</strong>.</p>
</div>
	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">El cálculo de la intensidad máxima admisible se realizará teniendo en cuenta el tipo de corriente, corriente continua y alterna, monofásica o trifásica.</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 32px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/07/formula1.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="113" src="https://www.fundacionforpro.org/wp-content/uploads/2015/07/formula1-300x113.jpg" class="vc_single_image-img attachment-medium" alt="formula1" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 32px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">En el <strong>Reglamento Electrotécnico de Baja Tensón</strong>, en la<strong> ITC BT 19</strong>, se prescribe el cálculo de secciones de conductores en instalaciones interiores o receptoras.</p>
<p style="text-align: justify;">Se muestra una tabla, en la cual se indican las intensidades máximas admisibles para cables de cobre a una temperatura del aire de 40 ºC y para distintos métodos de instalación, agrupamientos y tipos de cables. Esta tabla es un resumen de la última versión de la norma UNE 20460-5-523.</p>
<p style="text-align: justify;">Para otras temperaturas, métodos de instalación, agrupamientos y tipos de cable, así como para conductores enterrados, es necesario consultar dicha norma.</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 16px" ><span class="vc_empty_space_inner"></span></div>

<div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-vista_blue">
	<div class="vc_message_box-icon"><i class="fa fa-pencil-square-o"></i>
	</div><p style="text-align: center;"><span style="color: #339966;"><strong><a style="color: #339966;" href="https://www.fundacionforpro.org/wp-content/uploads/2015/07/ITC_BT_19.pdf">Consulta ITC_BT_19</a></strong></span></p>
</div><div class="vc_empty_space"  style="height: 16px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<h3 style="text-align: center;"><span style="color: #0000ff;">Cálculo de la sección teniendo en cuenta la caída de tensión en las líneas eléctricas</span></h3>
<p style="text-align: justify;">Al igual que hemos visto que las líneas que transportan la energía eléctrica están compuestas por conductores eléctricos de una cierta resistencia que, al ser recorridos por una corriente eléctrica, se calientan, y por lo tanto, producen una pérdida de potencia, también hay que pensar que los conductores de las líneas están coenctados en serie con los receptores, y al ser recorridos por la corriente ocasionan una caída de tensión.</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 16px" ><span class="vc_empty_space_inner"></span></div>

<div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-info">
	<div class="vc_message_box-icon"><i class="fa fa-info-circle"></i>
	</div><p style="text-align: justify;">La<strong> caída de tensión</strong> en las líneas puede llegar a ser un problema para el correcto funcionamiento de los receptores, ya que éstos están diseñados para trabajar a una cierta tensión.</p>
</div><div class="vc_empty_space"  style="height: 16px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Por ello, no sólo habrá que tener en cuenta el calentamiento del conductor para determinar su sección, sino que también será necesario no sobrepasar el porcentaje de caída de tensión prefijado en el REBT.</p>
<p style="text-align: justify;">Las siguientes expresiones serán las que utilizaremos para realizar el cálculo de la sección por caída de tensión:</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 32px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/07/formula2.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="188" src="https://www.fundacionforpro.org/wp-content/uploads/2015/07/formula2-300x188.jpg" class="vc_single_image-img attachment-medium" alt="formula2" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Estas expresiones están calculadas utilizando los parámetros de resistividad y conductividad que poseerían los conductores.</p>
<p style="text-align: justify;">En la siguiente tabla se ha calculado la conductividad que poseerían los conductores para diferentes temperaturas con la idea de tener en cuenta estos resultados a la hora de aplicar la norma UNE 20460-5-523.</p>
<p style="text-align: justify;">Además dependiendo del aislamiento del conductor, los valores de conductividad a considerar en función de la temperatura que alcanzará  serán los indicados (PVC 70 ºC, XLPE/EPR 90ºC).</p>

		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/07/m03u02-resistividad.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="83" src="https://www.fundacionforpro.org/wp-content/uploads/2015/07/m03u02-resistividad-300x83.jpg" class="vc_single_image-img attachment-medium" alt="m03u02-resistividad" /></div></a>
		</div> 
	</div> <div class="vc_empty_space"  style="height: 20px" ><span class="vc_empty_space_inner"></span></div>


	<div class="wpb_text_column wpb_content_element  ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">En el REBT se pueden consultar las caídas de tensión máximas admitidas según el tipo de instalación.</p>
<p style="text-align: justify;">La siguiente tabla nos muestra las más significativas:</p>

		</div> 
	</div> 
	<div class="wpb_single_image wpb_content_element  vc_align_center">
		<div class="wpb_wrapper">
			
			<a class="dt-mfp-item mfp-image dt-single-mfp-popup rollover rollover-zoom vc_single_image-img " href="https://www.fundacionforpro.org/wp-content/uploads/2015/07/cdt.jpg" target="_self"><div class="vc_single_image-wrapper   vc_box_border_grey"><img width="300" height="266" src="https://www.fundacionforpro.org/wp-content/uploads/2015/07/cdt-300x266.jpg" class="vc_single_image-img attachment-medium" alt="cdt" /></div></a>
		</div> 
	</div> <div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-vista_blue">
	<div class="vc_message_box-icon"><i class="fa fa-pencil-square-o"></i>
	</div><p style="text-align: justify;">Una vez realizados ambos cálculos se tendrá en cuenta <span style="text-decoration: underline;"><strong>el mayor valor obtenido,</strong></span> siendo la sección normalizada la correspondiente a dicho cálculo.</p>
</div><div class="vc_message_box vc_message_box-standard vc_message_box-rounded vc_color-info">
	<div class="vc_message_box-icon"><i class="fa fa-file-text-o"></i>
	</div><p style="text-align: justify;">La bibliografía utilizada para la elaboración de esta entrada han sido:</p>
<ul>
<li>Electrotecnia. Ed Paraninfo. Pablo Alcalde San Miguel</li>
<li>REBT. Reglamento Electrotécnico para Baja Tensión.</li>
</ul>
</div>
		</div> 
	</div> 
</div>
<p>La entrada <a rel="nofollow" href="https://www.fundacionforpro.org/blog/calculo-de-la-seccion-de-una-linea-electrica/">Parte 1/2: Cálculo de la Sección de una Línea Eléctrica</a> aparece primero en <a rel="nofollow" href="https://www.fundacionforpro.org">Fundación Forpro Albacete</a>.</p>
]]></content:encoded>
			<wfw:commentRss>https://www.fundacionforpro.org/blog/calculo-de-la-seccion-de-una-linea-electrica/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
